Jiangxi sword Fire Equipemnt Co., Ltd.

mobile app download QRcode
National Service Hotline

86-0790-6738876

Home > Products >
Products

fm200 hfc227 gas fire extinguisher cylinder price

fm200 hfc227 gas  fire extinguisher cylinder price 
Capacity types:40L ,70L, 90L, 120L, 150L,180L
fm200 hfc227 gas  fire extinguisher cylinder price 
pls contact me by email for fm200 hfc227 gas  fire extinguisher cylinder price 
Jiangxi Jianan Fire Fighting Equipment Co.,Ltd
Banqiao industrial Zone in Yushui District ,Xinyu City,Jiangxi Province,China ,338000
Tel: 0086-15679090956
Fax: 0086-0790-6738889
E-Mail: sales1@jxjaxf.net , felixleeyong@163.com

Prodcut advantage:

Accurate and reliable actions
 Simple operation and maintenance, beautiful appearance No harm to the human living environment
Mature fire extinguishing technology,no residue after fire extinguishing
The composition remaining life is short in the atmosphere Good storage and stable performance

Installation Notes:
• Installation requirements on equipment line, the equipment use 1.5 m2 multiple copper cores.There are five lines in total.two starting lines are in parallel, two feedback lines are in parallel, also one grounding line.
• The system requirements, when two or more protection areas adopt combined distribution systems. One combined distribution systems shall not protect over 8 area.
• The agent volume of the fire combined distribution systems shall be determined as maximum storage volume.The system agent storage volume shall be the sum of the fire extinguishing design volume and the residential volume in the pipes.
• The nozzle requirements, the protection height and radius shall comply with the following provisions:
The maximum protection height shall not exceed 6.5m;
The minimum protection height shall not be less than 0.3m:
When the installation height is less than 1.5m,the protection radius shall not exceed 4.Sm;
When the installation height is not be less than 1.5m, the protection radius shall not exceed 7.Sm; install the nozzle as the top side.the highest distance to the top shall not be exceed than O.Sm:
The protection area requirements :
The protection area shall be divided as per single enclosure space; when the suspended level and the floor in the same district need to be protected simultaneously, they may be combined into one protection area;
 When the pipe network fire extinguishing system is adopted, the area of the protection area shall
not exceed 800m2 , and the capacity shall not exceed 3600 m3;
The fire endurance of the fencing structure, doors and windows shall not be less than O.Sh; the fire endurance of the suspended ceiling shall not be less than 0.25h. The allowable pressure of the protection area fencing structure shall not be less than 1200 Pa.


Spare Parts and Parameter:



 Fire Protection Fm 200 services System design
Applications:

 

    Electronic computer room, a data processing center, telecommunications facilities, process control, expensive medical equipment, industrial equipment, library, museum and art gallery, clean room,flammable liquid storage area, etc.

 

    The place where the fire is easy to happen, like paint-spraying production line, aging-electrical equipment, rolling machine, printing machine, oil switch, oil immersed transformer, melt impregnating tank, tank, large generators, drying equipment, cement production process of pulverized coal, and the ship's engine room, cargo hold, etc.

 

Compositions:

 

    4.2mpa Hfc227ea Fire Suppression For Optional Zones is mainly composed by three parts. Extinguishing devices and pipe fittings and electrical accessories.Extinguishing devices are such things, like cylinder to fill and store fm200, frame and driving device(nitrogen cylinder) to trigger the storage cylinder to discharge agent and so on.

 

    Pipe fittings are those conduits to connect extinguishing device and guide agent into protective zone, like high pressure galvanized steel pipe and flange and elbow and so on.

 

Electrical accessories are those things which are used to detect and monitor whole protective area and control whole system, also warn people to evacuate and prevent from fire expansion. These integrated three parts will be efficient to detect and supervise and alarm and extinguish fire automatically.

 

    Here attached below is complete composition of whole system,

                Fm 200 Fire Protection System Hfc 227Ea Fire Extinguishing System

Company profile
Jiangxi Jian An Fire Fighting Equipment Co., Ltd, is a provincial level scientific& technological enterprise specially engaged in high technology, research, produce& sales the fire extinguisher in fire fighting equipment industry. Jian An company R&D the green environmental protection system fire fighting products independently. It contains the Aerosol fire extinguishing device, FM200 fire extinguishing device, Fire trace tube device. Our products are CNAS,UKASIS9001,CE approved, we are awarded the first fire control engineering technology research center in Jiangxi province of China.



Jiangxi Jianan Fire Fighting Equipment Co.,Ltd
Banqiao industrial Zone in Yushui District ,Xinyu City,Jiangxi Province,China ,338000
Tel: 0086-15679090956
Fax: 0086-0790-6738889
E-Mail: sales1@jxjaxf.net , felixleeyong@163.com